Evaluating Positive Pressure Ventilation in Large Structures: High-Rise Pressure Experiments(NISTIR 7412)

Evaluating Positive Pressure Ventilation in Large Structures: High-Rise Pressure Experiments(NISTIR 7412)

Author: nist

Publisher:

Published: 2013-11-21

Total Pages: 82

ISBN-13: 9781494249045

DOWNLOAD EBOOK

One hundred and sixty experiments were conducted in athirty-story vacant office building in Toledo, Ohio to evaluate the ability of fire department positive pressure ventilation fans to pressurize a stairwell in a high-rise structure in accordance with established performance metrics for fixed stairwell pressurization systems. Variables such as fan size, fan angle, setback distance, number of fans, orientation of fans, number of doors open and location of vents open were varied to examine capability and optimization of each. Fan size varied from 0.4 m (16 in) to 1.2 m (46 in). Fan angle ranged from 90 degrees to 80 degrees. The setback distance went from 0.6 m (2 ft) to 3.6 m (12 ft). Between one and nine fans were used which were located at three different exterior locations and three different interior locations. Fans were oriented both inseries and in parallel configurations. Doors throughout the building were opened and closed to evaluate the effects. Finally a door to the roof and a roof hatch were used as vent points. The measurements taken during the experiments included differential pressure, air temperature, carbon monoxide, metrological data and sound levels.PPV fans utilized correctlycan increase the effectiveness of fire fighters and survivability of occupants in high-rise buildings. In a high-rise building it is possible to increase the pressure of a stairwell to prevent the infiltration of smoke if fire crews configure the fans properly. Although many factors contribute and need to be considered for effective PPV operations, properly configured PPV can achieve stairwell pressures that are high enough to meet or exceed the performance metrics for fixed smoke control systems.


Book Synopsis Evaluating Positive Pressure Ventilation in Large Structures: High-Rise Pressure Experiments(NISTIR 7412) by : nist

Download or read book Evaluating Positive Pressure Ventilation in Large Structures: High-Rise Pressure Experiments(NISTIR 7412) written by nist and published by . This book was released on 2013-11-21 with total page 82 pages. Available in PDF, EPUB and Kindle. Book excerpt: One hundred and sixty experiments were conducted in athirty-story vacant office building in Toledo, Ohio to evaluate the ability of fire department positive pressure ventilation fans to pressurize a stairwell in a high-rise structure in accordance with established performance metrics for fixed stairwell pressurization systems. Variables such as fan size, fan angle, setback distance, number of fans, orientation of fans, number of doors open and location of vents open were varied to examine capability and optimization of each. Fan size varied from 0.4 m (16 in) to 1.2 m (46 in). Fan angle ranged from 90 degrees to 80 degrees. The setback distance went from 0.6 m (2 ft) to 3.6 m (12 ft). Between one and nine fans were used which were located at three different exterior locations and three different interior locations. Fans were oriented both inseries and in parallel configurations. Doors throughout the building were opened and closed to evaluate the effects. Finally a door to the roof and a roof hatch were used as vent points. The measurements taken during the experiments included differential pressure, air temperature, carbon monoxide, metrological data and sound levels.PPV fans utilized correctlycan increase the effectiveness of fire fighters and survivability of occupants in high-rise buildings. In a high-rise building it is possible to increase the pressure of a stairwell to prevent the infiltration of smoke if fire crews configure the fans properly. Although many factors contribute and need to be considered for effective PPV operations, properly configured PPV can achieve stairwell pressures that are high enough to meet or exceed the performance metrics for fixed smoke control systems.


Evaluating Positive Pressure Ventilation in Large Structures

Evaluating Positive Pressure Ventilation in Large Structures

Author: Stephen Kerber

Publisher:

Published: 2007

Total Pages: 0

ISBN-13:

DOWNLOAD EBOOK

PPV fans utilized correctly can increase the effectiveness of fire fighters and survivability of occupants in high-rise buildings. In a high-rise building it is possible to increase the pressure of a stairwell to prevent the infiltration of smoke if fire crews configure the fans properly. Although many factors contribute and need to be considered for effective PPV operations, properly configured PPV can achieve stairwell pressures that are high enough to meet or exceed the performance metrics for fixed smoke control systems.


Book Synopsis Evaluating Positive Pressure Ventilation in Large Structures by : Stephen Kerber

Download or read book Evaluating Positive Pressure Ventilation in Large Structures written by Stephen Kerber and published by . This book was released on 2007 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt: PPV fans utilized correctly can increase the effectiveness of fire fighters and survivability of occupants in high-rise buildings. In a high-rise building it is possible to increase the pressure of a stairwell to prevent the infiltration of smoke if fire crews configure the fans properly. Although many factors contribute and need to be considered for effective PPV operations, properly configured PPV can achieve stairwell pressures that are high enough to meet or exceed the performance metrics for fixed smoke control systems.


Evaluating Positive Pressure Ventilation in Large Structures

Evaluating Positive Pressure Ventilation in Large Structures

Author: nist

Publisher: Createspace Independent Publishing Platform

Published: 2013-11-22

Total Pages: 150

ISBN-13: 9781494252779

DOWNLOAD EBOOK

A series of six experiments was conducted in a highrise apartment building in Chicago, Illinois. One experiment on each of the fire floors utilized portable fans and the other utilized a large truck or trailer mounted fan. The two experiments on the third floor examined the effects of wind driven fire conditions. All of the experiments created high temperatures and dense smoke conditions in the hallway. Numerous configurations were used during the experiments and the ability of the fans to keep smoke and heat out of the stairwell was analyzed. The minimum design pressures of NFPA 92A were used as baselines to compare to the actual pressures measured.In this limited set of experiments portable fans and mounted fans were able to quickly clear the stairwell of smoke and maintain a pressure high enough to prevent smoke infiltration into the stairwell. Positive pressure ventilation fans utilized correctly can increase the effectiveness and safety of fire fighters and survivability of occupants in high-rise buildings. When configured properly PPV fans can meet or exceed previously established performance metrics for fixed smoke control systems.


Book Synopsis Evaluating Positive Pressure Ventilation in Large Structures by : nist

Download or read book Evaluating Positive Pressure Ventilation in Large Structures written by nist and published by Createspace Independent Publishing Platform. This book was released on 2013-11-22 with total page 150 pages. Available in PDF, EPUB and Kindle. Book excerpt: A series of six experiments was conducted in a highrise apartment building in Chicago, Illinois. One experiment on each of the fire floors utilized portable fans and the other utilized a large truck or trailer mounted fan. The two experiments on the third floor examined the effects of wind driven fire conditions. All of the experiments created high temperatures and dense smoke conditions in the hallway. Numerous configurations were used during the experiments and the ability of the fans to keep smoke and heat out of the stairwell was analyzed. The minimum design pressures of NFPA 92A were used as baselines to compare to the actual pressures measured.In this limited set of experiments portable fans and mounted fans were able to quickly clear the stairwell of smoke and maintain a pressure high enough to prevent smoke infiltration into the stairwell. Positive pressure ventilation fans utilized correctly can increase the effectiveness and safety of fire fighters and survivability of occupants in high-rise buildings. When configured properly PPV fans can meet or exceed previously established performance metrics for fixed smoke control systems.


Evaluating Positive Pressure Ventilation in Large Structures

Evaluating Positive Pressure Ventilation in Large Structures

Author: U.s. Department of Commerce

Publisher: CreateSpace

Published: 2014-01-31

Total Pages: 362

ISBN-13: 9781495298615

DOWNLOAD EBOOK

A series of experiments was run in a masonry educational building examining the ability of fire service Positive Pressure Ventilation (PPV) fans to limit smoke spread or to remove smoke from areas where potential occupants may be located. The PPV fans are able to accomplish this by creating pressures higher than that of the fire to manage where the smoke and hot gases flowed in the building. Preliminary experiments examined the pressure increase created by portable fans and mounted fans in different configurations and locations. The two main fire scenarios included a long hallway with classrooms and a gymnasium. Both scenarios included fires that produced a large amount of smoke and hot gases, and instrumentation was placed to assess tenability criteria and how PPV tactics can either increase or decrease tenability. Measurements included temperature, pressure, thermal imaging and video views.


Book Synopsis Evaluating Positive Pressure Ventilation in Large Structures by : U.s. Department of Commerce

Download or read book Evaluating Positive Pressure Ventilation in Large Structures written by U.s. Department of Commerce and published by CreateSpace. This book was released on 2014-01-31 with total page 362 pages. Available in PDF, EPUB and Kindle. Book excerpt: A series of experiments was run in a masonry educational building examining the ability of fire service Positive Pressure Ventilation (PPV) fans to limit smoke spread or to remove smoke from areas where potential occupants may be located. The PPV fans are able to accomplish this by creating pressures higher than that of the fire to manage where the smoke and hot gases flowed in the building. Preliminary experiments examined the pressure increase created by portable fans and mounted fans in different configurations and locations. The two main fire scenarios included a long hallway with classrooms and a gymnasium. Both scenarios included fires that produced a large amount of smoke and hot gases, and instrumentation was placed to assess tenability criteria and how PPV tactics can either increase or decrease tenability. Measurements included temperature, pressure, thermal imaging and video views.


Evaluating Positive Pressure Ventilation in Large Structures

Evaluating Positive Pressure Ventilation in Large Structures

Author: Stephen Kerber

Publisher:

Published: 2007

Total Pages: 72

ISBN-13:

DOWNLOAD EBOOK

PPV fans utilized correctly can increase the effectiveness of fire fighters and survivability of occupants in high-rise buildings. In a high-rise building it is possible to increase the pressure of a stairwell to prevent the infiltration of smoke if fire crews configure the fans properly. Although many factors contribute and need to be considered for effective PPV operations, properly configured PPV can achieve stairwell pressures that are high enough to meet or exceed the performance metrics for fixed smoke control systems.


Book Synopsis Evaluating Positive Pressure Ventilation in Large Structures by : Stephen Kerber

Download or read book Evaluating Positive Pressure Ventilation in Large Structures written by Stephen Kerber and published by . This book was released on 2007 with total page 72 pages. Available in PDF, EPUB and Kindle. Book excerpt: PPV fans utilized correctly can increase the effectiveness of fire fighters and survivability of occupants in high-rise buildings. In a high-rise building it is possible to increase the pressure of a stairwell to prevent the infiltration of smoke if fire crews configure the fans properly. Although many factors contribute and need to be considered for effective PPV operations, properly configured PPV can achieve stairwell pressures that are high enough to meet or exceed the performance metrics for fixed smoke control systems.


Evaluating positive pressure ventilation in large structures

Evaluating positive pressure ventilation in large structures

Author: Stephen Kerber

Publisher:

Published: 2007

Total Pages: 72

ISBN-13:

DOWNLOAD EBOOK


Book Synopsis Evaluating positive pressure ventilation in large structures by : Stephen Kerber

Download or read book Evaluating positive pressure ventilation in large structures written by Stephen Kerber and published by . This book was released on 2007 with total page 72 pages. Available in PDF, EPUB and Kindle. Book excerpt:


Evaluating Positive Pressure Ventilation in Large Structures

Evaluating Positive Pressure Ventilation in Large Structures

Author: Stephen Kerber

Publisher:

Published: 2008

Total Pages: 0

ISBN-13:

DOWNLOAD EBOOK

In the limited series of experiments in the long hallways of this masonry educational building, the use of positive pressure ventilation to increase pressure to reduce temperatures, limit smoke spread and increase visibility was effective. This series of experiments demonstrated that fire service positive pressure ventilation fans can be used successfully in large structures to increase tenability of potential victims and improve conditions for firefighting crews.


Book Synopsis Evaluating Positive Pressure Ventilation in Large Structures by : Stephen Kerber

Download or read book Evaluating Positive Pressure Ventilation in Large Structures written by Stephen Kerber and published by . This book was released on 2008 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt: In the limited series of experiments in the long hallways of this masonry educational building, the use of positive pressure ventilation to increase pressure to reduce temperatures, limit smoke spread and increase visibility was effective. This series of experiments demonstrated that fire service positive pressure ventilation fans can be used successfully in large structures to increase tenability of potential victims and improve conditions for firefighting crews.


Natural Ventilation for Infection Control in Health-care Settings

Natural Ventilation for Infection Control in Health-care Settings

Author: Y. Chartier

Publisher: World Health Organization

Published: 2009

Total Pages: 132

ISBN-13: 9241547855

DOWNLOAD EBOOK

This guideline defines ventilation and then natural ventilation. It explores the design requirements for natural ventilation in the context of infection control, describing the basic principles of design, construction, operation and maintenance for an effective natural ventilation system to control infection in health-care settings.


Book Synopsis Natural Ventilation for Infection Control in Health-care Settings by : Y. Chartier

Download or read book Natural Ventilation for Infection Control in Health-care Settings written by Y. Chartier and published by World Health Organization. This book was released on 2009 with total page 132 pages. Available in PDF, EPUB and Kindle. Book excerpt: This guideline defines ventilation and then natural ventilation. It explores the design requirements for natural ventilation in the context of infection control, describing the basic principles of design, construction, operation and maintenance for an effective natural ventilation system to control infection in health-care settings.


Evaluation of Fire Service Positive Pressure Ventilation Tactics on High-Rise Buildings

Evaluation of Fire Service Positive Pressure Ventilation Tactics on High-Rise Buildings

Author: S. Kerber

Publisher:

Published: 2007

Total Pages:

ISBN-13:

DOWNLOAD EBOOK


Book Synopsis Evaluation of Fire Service Positive Pressure Ventilation Tactics on High-Rise Buildings by : S. Kerber

Download or read book Evaluation of Fire Service Positive Pressure Ventilation Tactics on High-Rise Buildings written by S. Kerber and published by . This book was released on 2007 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:


Applications of Fire Research and Improvement

Applications of Fire Research and Improvement

Author: Michael R. Gunderson

Publisher: Jones & Bartlett Learning

Published: 2020-10-30

Total Pages: 119

ISBN-13: 1284206459

DOWNLOAD EBOOK

Applications of Fire Research and Improvement, Second Edition, provides the basic principles of research and research-based improvement methodologies for analyzing fire-related processes research.


Book Synopsis Applications of Fire Research and Improvement by : Michael R. Gunderson

Download or read book Applications of Fire Research and Improvement written by Michael R. Gunderson and published by Jones & Bartlett Learning. This book was released on 2020-10-30 with total page 119 pages. Available in PDF, EPUB and Kindle. Book excerpt: Applications of Fire Research and Improvement, Second Edition, provides the basic principles of research and research-based improvement methodologies for analyzing fire-related processes research.